Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X8C |
Synchrotron site | NSLS |
Beamline | X8C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2002-06-21 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 1.15 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 45.900, 81.800, 130.300 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.823 - 1.739 |
R-factor | 0.2086 |
Rwork | 0.205 |
R-free | 0.23620 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.019 |
RMSD bond angle | 1.078 |
Refinement software | PHENIX (1.7.1_743) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 19.820 |
High resolution limit [Å] | 1.740 |
Number of reflections | 47589 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | KDO disaccharide, magnesium chloride, zinc chloride, ethylene glycol, glycerol, PEG 4000, TRIS, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |