Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 108 |
Detector technology | CCD |
Collection date | 2009-08-14 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.00 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 92.700, 92.700, 130.100 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 43.662 - 1.600 |
R-factor | 0.1439 |
Rwork | 0.143 |
R-free | 0.16570 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 8tln |
RMSD bond length | 0.012 |
RMSD bond angle | 1.055 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.7_650)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.630 |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 44226 | |
<I/σ(I)> | 35.9 | 6.5 |
Completeness [%] | 100.0 | 100 |
Redundancy | 16.3 | 15.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291 | 50 mM Tris, 1.9 M cesium chloride, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |