3T1X
MglB R124A E127A Monomer
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | OTHER |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2010-11-16 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54180 |
Spacegroup name | I 4 |
Unit cell lengths | 74.250, 74.250, 76.220 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.050 - 2.910 |
R-factor | 0.40864 |
Rwork | 0.405 |
R-free | 0.46861 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3t1s |
RMSD bond length | 0.011 |
RMSD bond angle | 1.362 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC (5.5.0110) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 19.050 |
High resolution limit [Å] | 2.900 |
Number of reflections | 4223 |
Completeness [%] | 89.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 9.5 | 293.15 | 0.1M CHES, 30% PEG 400 , pH 9.5, VAPOR DIFFUSION, HANGING DROP, temperature 293.15K |