Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3SAU

MUTM Interrogation complex 6

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X25
Synchrotron siteNSLS
BeamlineX25
Temperature [K]100
Detector technologyCCD
Collection date2008-11-12
DetectorADSC QUANTUM 315
Wavelength(s)0.98
Spacegroup nameP 21 21 21
Unit cell lengths45.423, 93.436, 104.920
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.250 - 1.650
R-factor0.189
Rwork0.188
R-free0.21300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3gpx
RMSD bond length0.006
RMSD bond angle1.086
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.710
High resolution limit [Å]1.6501.650
Rmerge0.0570.493
Number of reflections52738
<I/σ(I)>13.4
Completeness [%]96.692.2
Redundancy5.54.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17291PEG 8K, SODIUM CACODYLATE, GLYCEROL, PH 7.0, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 291K

222624

PDB entries from 2024-07-17