Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X6A |
| Synchrotron site | NSLS |
| Beamline | X6A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-08-10 |
| Detector | ADSC QUANTUM 270 |
| Wavelength(s) | 0.97 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 58.407, 88.325, 89.106 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 14.992 - 1.000 |
| R-factor | 0.1329 |
| Rwork | 0.133 |
| R-free | 0.14180 |
| Structure solution method | SAD |
| RMSD bond length | 0.005 |
| RMSD bond angle | 1.163 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | SOLVE |
| Refinement software | PHENIX ((phenix.refine: 1.7_650)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 15.000 | 1.040 |
| High resolution limit [Å] | 1.000 | 1.000 |
| Number of reflections | 222826 | |
| <I/σ(I)> | 25.9 | |
| Completeness [%] | 90.1 | 71.5 |
| Redundancy | 4.2 | 3.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 22% PEG 3350, 50 mM Tris-HCl, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |