Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ELLIOTT GX-20 |
Temperature [K] | 298 |
Detector technology | AREA DETECTOR |
Collection date | 1991-06-11 |
Detector | San Diego Multiwire Systems |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 72.740, 78.490, 114.340 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.910 - 3.000 |
Rwork | 0.198 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.014 |
RMSD bond angle | 4.000 |
Data reduction software | San (Diego Multiwire Systems) |
Data scaling software | San (Diego Multiwire Systems) |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | |
High resolution limit [Å] | 3.000 |
Number of reflections | 8250 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | batch | 4.75 | 298 | 11.5% PEG 8000, 0.05 M sodium acetate, 2 mM lactose, pH 4.75, batch, temperature 298K |