Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3RBZ

MthK channel, Ca2+-bound

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.2
Synchrotron siteALS
Beamline5.0.2
Temperature [K]100
Detector technologyCCD
Collection date2005-11-19
DetectorADSC QUANTUM 315
Wavelength(s)1.0
Spacegroup nameP 61 2 2
Unit cell lengths138.558, 138.558, 371.620
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution48.500 - 3.400
R-factor0.259
Rwork0.257
R-free0.28770
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)PDB ENTRIES 1LNQ 3ldc 2aef
RMSD bond length0.012
RMSD bond angle1.272
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.6.4_486))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.5003.390
High resolution limit [Å]3.4003.390
Number of reflections28010
<I/σ(I)>2.1
Completeness [%]93.656.6
Redundancy11.35.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.529526% PEG 350-MME, 0.2 M CaCl2, 0.1 M MES, VAPOR DIFFUSION, HANGING DROP, temperature 295K, pH 6.5

225399

PDB entries from 2024-09-25

PDB statisticsPDBj update infoContact PDBjnumon