Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3R65

MthK channel pore E92Q mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2011-02-21
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.9790
Spacegroup nameP 4 21 2
Unit cell lengths63.560, 63.560, 43.973
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.430 - 1.800
R-factor0.20601
Rwork0.205
R-free0.22520
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ldc
RMSD bond length0.009
RMSD bond angle1.087
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareAMoRE
Refinement softwareREFMAC (5.5.0102)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]31.4301.850
High resolution limit [Å]1.8001.800
Number of reflections7959
<I/σ(I)>29.31.5
Completeness [%]90.274.8
Redundancy9.65.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP62933.0-3.5 M 1,6-Hexandiol, 100 mM MES, pH 6.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon