Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3QKU

Mre11 Rad50 binding domain in complex with Rad50 and AMP-PNP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 12.3.1
Synchrotron siteALS
Beamline12.3.1
Temperature [K]100
Detector technologyCCD
Collection date2007-11-01
DetectorADSC QUANTUM 315
Spacegroup nameP 65 2 2
Unit cell lengths177.398, 177.398, 130.423
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution50.000 - 3.300
R-factor0.26052
Rwork0.258
R-free0.30838
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1us8
RMSD bond length0.010
RMSD bond angle1.223
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]153.6003.387
High resolution limit [Å]3.3003.301
Rmerge0.0480.660
Number of reflections18667
<I/σ(I)>35.73.6
Completeness [%]99.799.41
Redundancy9.810.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293100 mM Tris, 200-300 mM lithium sulfate, 12-13% PEG3350, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon