3QB9
Mycobacterium tuberculosis bacterioferritin, BfrA
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL7-1 |
| Synchrotron site | SSRL |
| Beamline | BL7-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-12-03 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.0972109 |
| Spacegroup name | I 4 |
| Unit cell lengths | 124.343, 124.343, 174.976 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 39.321 - 2.110 |
| R-factor | 0.1842 |
| Rwork | 0.178 |
| R-free | 0.23630 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.982 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Refinement software | PHENIX ((phenix.refine: 1.6.4_486)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 39.321 |
| High resolution limit [Å] | 2.110 |
| Rmerge | 0.084 |
| Number of reflections | 75962 |
| <I/σ(I)> | 13.303 |
| Completeness [%] | 99.3 |
| Redundancy | 9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 1.8 M NaCl, 100 mM Tris-HCl (pH 8.0), 25 mM MgCl2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |