Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3PXJ

Tandem Ig repeats of Dlar

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2010-04-25
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.97242
Spacegroup nameP 1 21 1
Unit cell lengths72.957, 77.513, 81.726
Unit cell angles90.00, 101.08, 90.00
Refinement procedure
Resolution41.385 - 2.300
R-factor0.2251
Rwork0.223
R-free0.26130
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3pxh
RMSD bond length0.032
RMSD bond angle1.657
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER (2.1.4)
Refinement softwarePHENIX (1.6.4_486)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.380
High resolution limit [Å]2.3004.9502.300
Rmerge0.1170.1080.415
Number of reflections39287
<I/σ(I)>12.3
Completeness [%]98.795.798.2
Redundancy2.72.92
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP729350 mM imidazole pH 7.0, 10 mM ammonium sulfate, 20% (w/v) PEG 2000 MME, VAPOR DIFFUSION, HANGING DROP, temperature 293K

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon