3PO1
Thrombin in complex with Benzothiazole Guanidine
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-09-15 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.9795 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 68.662, 71.414, 71.880 |
Unit cell angles | 90.00, 99.82, 90.00 |
Refinement procedure
Resolution | 27.176 - 1.650 |
R-factor | 0.2287 |
Rwork | 0.227 |
R-free | 0.26040 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.367 |
Data reduction software | MOSFLM |
Data scaling software | SCALA (3.2.5) |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 70.890 | 27.176 | 1.690 |
High resolution limit [Å] | 1.650 | 7.380 | 1.650 |
Rmerge | 0.056 | 0.041 | 0.340 |
Total number of observations | 1297 | 9255 | |
Number of reflections | 39772 | ||
<I/σ(I)> | 13.6 | 13.9 | 2.2 |
Completeness [%] | 96.8 | 92.6 | 95.3 |
Redundancy | 3.3 | 2.9 | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 7.3 | 298 | 0.05 M sodium phosphate, 28% PEG8000, pH 7.3, EVAPORATION, temperature 298K |