Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3PMU

Endothiapepsin in complex with a fragment

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2010-06-25
DetectorRAYONIX MX-225
Wavelength(s)0.91841
Spacegroup nameP 1 21 1
Unit cell lengths45.190, 73.740, 52.480
Unit cell angles90.00, 109.32, 90.00
Refinement procedure
Resolution19.698 - 1.430
R-factor0.1661
Rwork0.165
R-free0.18870
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1oew
RMSD bond length0.005
RMSD bond angle1.070
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.6.4_486))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.450
High resolution limit [Å]1.4301.430
Number of reflections59547
<I/σ(I)>14.32.3
Completeness [%]100.0100
Redundancy3.12.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62890.1M NH4Ac, 0.1M Acetate Buffer pH 4.6, 26% PEG 4000, VAPOR DIFFUSION, SITTING DROP, temperature 277K, temperature 289K

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon