3PI0
Endothiapepsin in complex with a fragment
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.3 |
Synchrotron site | BESSY |
Beamline | 14.3 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-10-21 |
Detector | RAYONIX SX-165mm |
Wavelength(s) | 0.89440 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.310, 73.030, 52.670 |
Unit cell angles | 90.00, 109.41, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.640 |
Rwork | 0.151 |
R-free | 0.18380 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1oew |
RMSD bond length | 0.008 |
RMSD bond angle | 0.025 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 1.670 |
High resolution limit [Å] | 1.640 | 1.640 |
Number of reflections | 38684 | |
<I/σ(I)> | 20.4 | 3 |
Completeness [%] | 100.0 | 100 |
Redundancy | 3 | 2.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 289 | 0.1M NH4Ac, 0.1M Acetate Buffer pH 4.6, 26% PEG 4000, VAPOR DIFFUSION, SITTING DROP, temperature 277K, temperature 289K |