3O2X
MMP-13 in complex with selective tetrazole core inhibitor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2001-01-04 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 73.864, 95.257, 120.076 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.720 - 1.900 |
| R-factor | 0.17838 |
| Rwork | 0.177 |
| R-free | 0.20956 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.110 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | AMoRE |
| Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.970 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Number of reflections | 56980 | |
| <I/σ(I)> | 16.4 | 3.8 |
| Completeness [%] | 84.3 | 79.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.7 | 277 | Lithium sulfate, HEPES buffer,pH 7.7, VAPOR DIFFUSION, HANGING DROP, temperature 277K |