3O1F
P1 crystal form of E. coli ClpS at 1.4 A resolution
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2010-01-19 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 1 |
| Unit cell lengths | 28.025, 28.051, 51.624 |
| Unit cell angles | 80.50, 77.88, 72.30 |
Refinement procedure
| Resolution | 22.488 - 1.400 |
| R-factor | 0.1746 |
| Rwork | 0.173 |
| R-free | 0.19720 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.194 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.4_129) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 1.450 |
| High resolution limit [Å] | 1.400 | 3.020 | 1.400 |
| Rmerge | 0.036 | 0.030 | 0.150 |
| Number of reflections | 23654 | ||
| <I/σ(I)> | 17.3 | ||
| Completeness [%] | 82.4 | 88.5 | 32 |
| Redundancy | 3.7 | 3.5 | 3.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 300 | 0.2M Ammonium Formate, 20% PEG 3350, VAPOR DIFFUSION, HANGING DROP, pH 7, temperature 300K |