3NVG
MIHFGN segment 137-142 from mouse prion
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-11-20 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.0048 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 27.280, 4.771, 31.476 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.620 - 1.480 |
R-factor | 0.1835 |
Rwork | 0.181 |
R-free | 0.20490 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.013 |
RMSD bond angle | 1.346 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER (1.3.2) |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 90.000 | 90.000 | 1.620 |
High resolution limit [Å] | 1.480 | 2.560 | 1.480 |
Rmerge | 0.154 | 0.108 | 0.452 |
Number of reflections | 801 | ||
<I/σ(I)> | 7 | ||
Completeness [%] | 90.9 | 99.5 | 68.8 |
Redundancy | 5.3 | 5.3 | 3.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 100mM HEPES 7.5, vapor diffusion, hanging drop, temperature 298K |