RADA RECOMBINASE D302K MUTANT IN COMPLEX with AMP-PNP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2010-05-20
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.98
Spacegroup nameP 61
Unit cell lengths84.970, 84.970, 104.320
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution30.000 - 1.900
R-factor0.188
Rwork0.188
R-free0.21400
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)1t4g
RMSD bond length0.015
RMSD bond angle1.730
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.980
High resolution limit [Å]1.9001.900
Rmerge0.0490.278
Number of reflections33350
<I/σ(I)>27.110
Completeness [%]99.198.6
Redundancy9.59.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2942mM AMP-PNP, 4-5% PEG 3350, 50 MM MGCL2, 0.4 M NACL, 50 MM TRIS-HCL and 14% sucrose, pH 6-8, VAPOR DIFFUSION, HANGING DROP, temperature 294.0K

222415