Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2008-03-20 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 161.735, 65.062, 50.415 |
Unit cell angles | 90.00, 90.23, 90.00 |
Refinement procedure
Resolution | 42.706 - 2.392 |
R-factor | 0.1901 |
Rwork | 0.188 |
R-free | 0.22230 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.689 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.490 |
High resolution limit [Å] | 2.392 | 2.400 |
Number of reflections | 20284 | |
Completeness [%] | 97.2 | 92.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 288 | 0.1M MES monohydrate, pH 6.5, 12% w/v PEG 20000, VAPOR DIFFUSION, HANGING DROP, temperature 288K |