3MZQ
RNase crystals grown by the hanging drop method
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL7-1 |
Synchrotron site | SSRL |
Beamline | BL7-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-11-25 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9795 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 64.240, 64.240, 63.680 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.000 - 1.500 |
R-factor | 0.17665 |
Rwork | 0.176 |
R-free | 0.19335 |
Structure solution method | Rigid body refinement |
Starting model (for MR) | Structure refinement using the data collected for the loop method (used PDB code: 3DH5 for MR for the loop method) |
RMSD bond length | 0.018 |
RMSD bond angle | 1.702 |
Data reduction software | XDS |
Data scaling software | XDS |
Refinement software | REFMAC (5.5.0102) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 29.000 | 1.540 |
High resolution limit [Å] | 1.500 | 1.500 |
Rmerge | 0.046 | 0.446 |
Number of reflections | 24750 | |
<I/σ(I)> | 23.63 | 3.9 |
Completeness [%] | 99.8 | |
Redundancy | 5.9 | 5.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 295 | 1.7M Ammonium sulfate, 2M NaCal, 0.1M Sodium acetate, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 295K |