Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3MK9

Stabilized Ricin Immunogen 1-33/44-198

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsBRUKER AXS MICROSTAR
Temperature [K]100
Detector technologyCCD
Collection date2010-02-21
DetectorBRUKER SMART 6000
Wavelength(s)1.54
Spacegroup nameI 2 2 2
Unit cell lengths51.744, 72.767, 96.382
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution58.030 - 2.080
R-factor0.21108
Rwork0.210
R-free0.23603
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ifs
RMSD bond length0.006
RMSD bond angle1.111
Data reduction softwareSAINT
Data scaling softwareSADABS
Phasing softwareAMoRE
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]58.0702.170
High resolution limit [Å]2.0802.080
Number of reflections10903
<I/σ(I)>20.183.88
Completeness [%]96.677.1
Redundancy9.613.01
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.4290Protein Buffer: 50mM MES pH 6.4, 200mM NaCl, 2mM BME, Crystallization Solution: 0.17M Ammonium Sulfate, 25.5% w/v PEG 4000, 15% v/v Glycerol , VAPOR DIFFUSION, HANGING DROP, temperature 290K

222624

PDB entries from 2024-07-17