3LVV

BSO-inhibited ScGCL

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 14-BM-C
Synchrotron siteAPS
Beamline14-BM-C
Temperature [K]100
Detector technologyCCD
Collection date2008-12-06
DetectorADSC QUANTUM 315
Wavelength(s)0.9
Spacegroup nameP 43 21 2
Unit cell lengths117.863, 117.863, 165.562
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.350 - 2.200
R-factor0.18302
Rwork0.181
R-free0.23851
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ig5
RMSD bond length0.020
RMSD bond angle1.883
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.280
High resolution limit [Å]2.2002.200
Rmerge0.0570.503
Number of reflections59891
<I/σ(I)>25.42.8
Completeness [%]100.0100
Redundancy18.77
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.8291100 mM Hepes, pH 6.8, 12% PEG 400, VAPOR DIFFUSION, SITTING DROP, temperature 291K

223166