3LSA
Padron0.9-OFF (non-fluorescent state)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X10SA |
| Synchrotron site | SLS |
| Beamline | X10SA |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-02-21 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 1.0000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 73.334, 104.262, 123.102 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 30.000 - 1.790 |
| R-factor | 0.1606 |
| Rwork | 0.159 |
| R-free | 0.19021 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2iov |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.333 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.5.0063) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.860 |
| High resolution limit [Å] | 1.790 | 1.790 |
| Number of reflections | 83955 | |
| <I/σ(I)> | 2.3 | |
| Completeness [%] | 99.3 | 98.3 |
| Redundancy | 3.1 | 2.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |