3LF3
Crystal Structure of Fast Fluorescent Timer Fast-FT
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 48.838, 42.517, 61.766 |
Unit cell angles | 90.00, 112.07, 90.00 |
Refinement procedure
Resolution | 29.762 - 1.150 |
R-factor | 0.15 |
Rwork | 0.149 |
R-free | 0.17700 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.538 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | PHENIX |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 30.000 | 30.000 | 1.190 |
High resolution limit [Å] | 1.150 | 2.480 | 1.150 |
Rmerge | 0.048 | 0.034 | 0.457 |
Number of reflections | 83298 | ||
<I/σ(I)> | 11.6 | ||
Completeness [%] | 99.7 | 99.7 | 97.3 |
Redundancy | 3.6 | 3.7 | 2.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |