Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3KL8

CaMKIINtide Inhibitor Complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]100
Detector technologyCCD
Collection date2009-02-09
DetectorADSC QUANTUM 315r
Wavelength(s).9537
Spacegroup nameP 1 21 1
Unit cell lengths72.410, 83.080, 145.130
Unit cell angles90.00, 101.93, 90.00
Refinement procedure
Resolution71.708 - 3.372
R-factor0.234
Rwork0.230
R-free0.28100
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.101
Data reduction softwareMOSFLM (3.3.9)
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]83.1003.600
High resolution limit [Å]3.4003.400
Number of reflections21523
Completeness [%]98.398.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION729320% 2-methyl-2,4-pentanediol, pH 7.0, VAPOR DIFFUSION, temperature 293K

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon