3KJE
Empty state of CooC1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR591 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2008-02-20 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.5418 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 80.110, 80.110, 76.850 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.380 - 2.300 |
Rwork | 0.231 |
R-free | 0.28260 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | CNS (1.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.400 |
High resolution limit [Å] | 2.300 | 2.300 |
Number of reflections | 12969 | |
<I/σ(I)> | 34.65 | |
Completeness [%] | 99.6 | 99.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 290 | 8% PEG3350, 0.1 M HEPES-NaOH pH7.5, 0.2M L-proline, VAPOR DIFFUSION, HANGING DROP, temperature 290K |