3JRP
SEC13 with NUP145C (AA109-179) insertion blade
Experimental procedure
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-10-27 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9792 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 68.280, 93.878, 55.047 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.717 - 2.600 |
R-factor | 0.221 |
Rwork | 0.217 |
R-free | 0.25400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2pm6 |
RMSD bond length | 0.003 |
RMSD bond angle | 0.679 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.660 |
High resolution limit [Å] | 2.600 | 2.600 |
Number of reflections | 11148 | |
Completeness [%] | 97.8 | 96.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.3 | 289 | 0.1M Tris, 22% PEG 4000, 0.25 M LiCl, pH 8.3, VAPOR DIFFUSION, HANGING DROP, temperature 289K |