Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 110 |
Detector technology | IMAGE PLATE |
Collection date | 1998-09-05 |
Detector | RIGAKU RAXIS II |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 59.227, 75.915, 81.547 |
Unit cell angles | 90.00, 94.06, 90.00 |
Refinement procedure
Resolution | 32.440 - 3.000 |
R-factor | 0.261 |
Rwork | 0.250 |
R-free | 0.32000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | T4 lysozyme I3P mutant |
RMSD bond angle | 0.020 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | AMoRE |
Refinement software | CCP4 ((refmac)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 32.440 | |
High resolution limit [Å] | 3.000 | 3.000 |
Number of reflections | 17925 | |
Completeness [%] | 96.5 | 99.8 |
Redundancy | 4.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 20% PEG 3400, 50 mM ammonium sulfate, Tris, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |