3J8W
Cryo-EM reconstruction of quasi-HPV16 complex with H263.A2 Fab
EM specimen
Vitrification | Yes |
Instrument | GATAN CRYOPLUNGE 3 |
EM Data Collection
Microscope | JEOL 2100 |
Electron Gun | LAB6 |
Accelerating Voltage (kV) | 200 |
Cs (mm) | 2 |
Detector | GATAN ULTRASCAN 4000 (4k x 4k) |
Number of Images | 264 |
3D Reconstruction
Method | SINGLE PARTICLE |
Resolution (Å) | 13 |
Software | Situs,UCSF Chimera,Auto3DEM |
Symmetry | I |