3IYL
Atomic CryoEM Structure of a Nonenveloped Virus Suggests How Membrane Penetration Protein is Primed for Cell Entry
EM specimen
Vitrification | Yes |
Instrument | FEI VITROBOT MARK I |
Method | Blot for 7-9 seconds before plunging |
EM Data Collection
Microscope | FEI TITAN KRIOS |
Electron Gun | FIELD EMISSION GUN |
Accelerating Voltage (kV) | 300 |
Cs (mm) | 2.7 |
Detector | KODAK SO-163 FILM |
3D Reconstruction
Method | SINGLE PARTICLE |
Resolution (Å) | 3.3 |
Software | FREALIGN,IMIRS |
Symmetry | I |