3IBV
Karyopherin cytosolic state
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2008-04-24 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 0.96 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 119.900, 130.100, 173.900 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.900 - 3.100 |
Rwork | 0.275 |
R-free | 0.31300 |
Structure solution method | MIR |
RMSD bond length | 0.012 |
RMSD bond angle | 1.606 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | SHELXS |
Refinement software | CNS |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 49.900 | 3.200 | |
High resolution limit [Å] | 3.100 | 10.000 | 3.100 |
Rmerge | 0.092 | 0.033 | 0.750 |
Number of reflections | 48907 | 1599 | 4107 |
<I/σ(I)> | 17.22 | 44.8 | 2.3 |
Completeness [%] | 97.7 | 97.2 | 92.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 100mM MES, pH6.5, 30% PEG400, 160mM CaCl2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 100mM MES, pH6.5, 30% PEG400, 160mM CaCl2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 100mM MES, pH6.5, 30% PEG400, 160mM CaCl2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 100mM MES, pH6.5, 30% PEG400, 160mM CaCl2, VAPOR DIFFUSION, HANGING DROP, temperature 298K |