Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3HS8

Intersectin 1-peptide-AP2 alpha ear complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2007-07-17
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameP 21 21 2
Unit cell lengths64.484, 120.412, 32.220
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution30.100 - 1.900
R-factor0.191
Rwork0.189
R-free0.23500
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.018
RMSD bond angle1.645
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareREFMAC
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]40.00040.0001.970
High resolution limit [Å]1.9004.0901.900
Rmerge0.0300.0190.130
Number of reflections19195
<I/σ(I)>27.513
Completeness [%]93.394.483.2
Redundancy2.92.92.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP829120% PEG4000, 100mM HEPES, 10% Isopropanol, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 291.0K

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon