Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-05-22 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.072 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 59.218, 85.813, 188.578 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.730 - 2.100 |
R-factor | 0.18224 |
Rwork | 0.179 |
R-free | 0.23499 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1p3w |
RMSD bond length | 0.018 |
RMSD bond angle | 1.698 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.730 | 2.200 |
High resolution limit [Å] | 2.100 | 2.100 |
Rmerge | 0.107 | 0.370 |
Number of reflections | 54053 | |
<I/σ(I)> | 13.1 | 5.7 |
Completeness [%] | 100.0 | 100 |
Redundancy | 7.1 | 7.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.7 | 293 | 100mM HEPES, 10% PEG 6000, pH 6.7, VAPOR DIFFUSION, SITTING DROP, temperature 293K |