Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3F1I

Human ESCRT-0 Core Complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2008-06-11
Wavelength(s)1.0000
Spacegroup nameI 41
Unit cell lengths78.059, 78.059, 152.849
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.770 - 2.300
R-factor0.23941
Rwork0.239
R-free0.25305
Structure solution methodSIRAS
RMSD bond length0.015
RMSD bond angle1.388
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHARP
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]69.5002.380
High resolution limit [Å]2.3002.300
Number of reflections20041
<I/σ(I)>23.44.2
Redundancy7.56
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP529414% MPD, 100 mM CaCl2, 0.1 M sodium acetate, pH 5.0, VAPOR DIFFUSION, HANGING DROP, temperature 294K

221716

PDB entries from 2024-06-26

PDB statisticsPDBj update infoContact PDBjnumon