Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3DZP

Thaumatin by LB nanotemplate method after high X-Ray dose on ESRF ID29 beamline

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]110
Detector technologyCCD
Collection date2007-04-29
DetectorADSC QUANTUM 315
Wavelength(s)0.9787
Spacegroup nameP 41 21 2
Unit cell lengths57.796, 57.796, 150.107
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.790 - 1.510
R-factor0.158
Rwork0.156
R-free0.18300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rqw
RMSD bond length0.007
RMSD bond angle1.105
Data reduction softwareMOSFLM
Data scaling softwareSCALA (3.2.25)
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.9361.580
High resolution limit [Å]1.5001.500
Rmerge0.0670.502
Total number of observations45476
Number of reflections41813
<I/σ(I)>1.5
Completeness [%]100.0100
Redundancy7.57.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5293100mM ADA, 1M Na/K-tartrate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon