3DO0

Thermolysin by classical hanging drop method after high X-Ray dose on esrf ID14-2 beamline

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]110
Detector technologyCCD
Collection date2007-05-15
DetectorADSC QUANTUM 4
Wavelength(s)0.93
Spacegroup nameP 61 2 2
Unit cell lengths92.724, 92.724, 128.600
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution80.320 - 1.360
R-factor0.224
Rwork0.223
R-free0.25500
RMSD bond length0.011
RMSD bond angle1.202
Data reduction softwareMOSFLM
Data scaling softwareSCALA (3.2.25)
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]80.3221.380
High resolution limit [Å]1.3601.310
Rmerge0.2750.154
Total number of observations3967
Number of reflections64386
<I/σ(I)>2.7
Completeness [%]81.224.1
Redundancy5.31.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6293DMSO, Ammonium sulfate, MES, hanging drop, 293K, pH6.0, VAPOR DIFFUSION, HANGING DROP