3DCC
Use of Carbonic Anhydrase II, IX Active-Site Mimic, for the Purpose of Screening Inhibitors for Possible Anti-Cancer Properties
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2008-04-01 |
| Detector | RIGAKU RAXIS IV++ |
| Wavelength(s) | 1.54178 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 42.890, 41.900, 73.000 |
| Unit cell angles | 90.00, 104.61, 90.00 |
Refinement procedure
| Resolution | 20.000 - 1.600 |
| Rwork | 0.146 |
| R-free | 0.20600 |
| Structure solution method | AB INITIO |
| Starting model (for MR) | 1moo |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.024 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | SHELX |
| Refinement software | SHELXL-97 |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.660 |
| High resolution limit [Å] | 1.600 | 1.600 |
| Number of reflections | 26650 | |
| Completeness [%] | 79.8 | 76.5 |
| Redundancy | 2.1 | 2.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 9 | 298 | 1.3M sodium citrate, 100mM Tris-HCl, pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |






