3D9Z
Use of Carbonic Anhydrase II, IX Active-Site Mimic, for the Purpose of Screening Inhibitors for Possible Anti-Cancer Properties
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2008-04-01 |
| Detector | RIGAKU RAXIS IV++ |
| Wavelength(s) | 1.54178 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 42.850, 41.840, 72.900 |
| Unit cell angles | 90.00, 104.61, 90.00 |
Refinement procedure
| Resolution | 20.000 - 1.650 |
| Rwork | 0.145 |
| R-free | 0.19000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1moo |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.024 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SHELX |
| Refinement software | SHELXL-97 |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.710 |
| High resolution limit [Å] | 1.650 | 1.650 |
| Number of reflections | 28166 | |
| Completeness [%] | 93.0 | 89.2 |
| Redundancy | 2.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 9 | 298 | 1.3M sodium citrate, 100mM Tris-HCl, pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |