Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3CK0

ANTI-ANTI-IDIOTYPIC ANTIBODY AGAINST HUMAN ANGIOTENSIN II, COMPLEX WITH HUMAN ANGIOTENSIN II

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]298
Detector technologyIMAGE PLATE
DetectorRIGAKU
Spacegroup nameP 43 21 2
Unit cell lengths84.440, 84.440, 158.970
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution8.000 - 3.000
R-factor0.2
Rwork0.200
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.520
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareX-PLOR (3.8)
Data quality characteristics
 Overall
Low resolution limit [Å]100.000
High resolution limit [Å]3.000
Number of reflections10218
Completeness [%]84.0
Redundancy2.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17.5pH 7.5

224004

PDB entries from 2024-08-21

PDB statisticsPDBj update infoContact PDBjnumon