3C3R
ALIX BRO1 CHMP4C complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2008-01-20 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.5418 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 120.907, 62.402, 76.354 |
Unit cell angles | 90.00, 121.62, 90.00 |
Refinement procedure
Resolution | 33.860 - 2.020 |
R-factor | 0.24599 |
Rwork | 0.243 |
R-free | 0.28849 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.016 |
RMSD bond angle | 1.536 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | REFMAC |
Refinement software | REFMAC (5.2.0005) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.090 |
High resolution limit [Å] | 2.020 | 2.020 |
Number of reflections | 30381 | |
Completeness [%] | 95.5 | 81 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 277 | 10% PEG 2,000, 100mM Na MES pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 277K |