Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | SIEMENS |
| Temperature [K] | 293 |
| Detector technology | AREA DETECTOR |
| Collection date | 1994-01-01 |
| Detector | SIEMENS HI-STAR |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 164.320, 57.510, 85.360 |
| Unit cell angles | 90.00, 102.66, 90.00 |
Refinement procedure
| Resolution | 10.000 - 2.000 |
| Rwork | 0.189 |
| R-free | 0.23800 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.568 |
| Data scaling software | X-GEN |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 10.000 |
| High resolution limit [Å] | 2.000 |
| Number of reflections | 87623 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | SMALL TUBES | 7.4 | 293 | 40% ammonium sulphate 5mM EDTA, 100mM triethylamine, pH 7.4, SMALL TUBES, temperature 293K |