Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

3UU8

The GLIC pentameric Ligand-Gated Ion Channel Loop2-24' mutant reduced in solution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2009-04-18
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.98011
Spacegroup nameC 1 2 1
Unit cell lengths181.350, 133.470, 159.940
Unit cell angles90.00, 102.21, 90.00
Refinement procedure
Resolution34.110 - 3.250
R-factor0.2259
Rwork0.226
R-free0.23380
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3eam
RMSD bond length0.010
RMSD bond angle1.130
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareBUSTER (2.11.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.1103.430
High resolution limit [Å]3.2503.250
Rmerge0.1160.578
Number of reflections57137
<I/σ(I)>8.22.1
Completeness [%]97.398.2
Redundancy2.92.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP429315% PEG4000, 0.4 M sodium thiocyanate, 0.1 M sodium acetate, pH 4.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K

231029

PDB entries from 2025-02-05

PDB statisticsPDBj update infoContact PDBjnumon