3T87
Thermolysin In Complex With UBTLN28
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.2 |
| Synchrotron site | BESSY |
| Beamline | 14.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-06-25 |
| Detector | RAYONIX MX-225 |
| Wavelength(s) | 0.91841 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 92.700, 92.700, 131.100 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 34.232 - 1.280 |
| R-factor | 0.1065 |
| Rwork | 0.105 |
| R-free | 0.12700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 8tln |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.353 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.7_650)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.300 |
| High resolution limit [Å] | 1.280 | 1.280 |
| Number of reflections | 83248 | |
| <I/σ(I)> | 30.6 | 5.2 |
| Completeness [%] | 97.0 | 99.1 |
| Redundancy | 10.7 | 9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291 | 50 mM Tris, 1.9 M cesium chloride, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |