Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3T1X

MglB R124A E127A Monomer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsOTHER
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2010-11-16
DetectorMAR scanner 345 mm plate
Wavelength(s)1.54180
Spacegroup nameI 4
Unit cell lengths74.250, 74.250, 76.220
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.050 - 2.910
R-factor0.40864
Rwork0.405
R-free0.46861
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3t1s
RMSD bond length0.011
RMSD bond angle1.362
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0110)
Data quality characteristics
 Overall
Low resolution limit [Å]19.050
High resolution limit [Å]2.900
Number of reflections4223
Completeness [%]89.0
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP9.5293.150.1M CHES, 30% PEG 400 , pH 9.5, VAPOR DIFFUSION, HANGING DROP, temperature 293.15K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon