Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X8C |
| Synchrotron site | NSLS |
| Beamline | X8C |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2001-09-10 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 1.15 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 45.600, 80.900, 130.600 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.773 - 1.489 |
| R-factor | 0.1895 |
| Rwork | 0.187 |
| R-free | 0.21210 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | STARTING MODEL: PDB ENTRY 1Q9O S45-18 FAB UNLIGANDED |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.200 |
| Refinement software | PHENIX (1.7.1_743) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 19.770 |
| High resolution limit [Å] | 1.490 |
| Number of reflections | 73625 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |