Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2009-12-12
DetectorRAYONIX MX-225
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths69.900, 71.100, 72.900
Unit cell angles90.00, 100.60, 90.00
Refinement procedure
Resolution34.354 - 1.780
R-factor0.1559
Rwork0.154
R-free0.18520
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1h8d
RMSD bond length0.008
RMSD bond angle1.055
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.6.4_486))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.810
High resolution limit [Å]1.7801.780
Number of reflections32972
<I/σ(I)>14.22.1
Completeness [%]97.999.4
Redundancy32.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5277.1515% PEG 8000, 20mM sodium phosphate, 175mM sodium chloride, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277.15K

219869

PDB entries from 2024-05-15