3RM8
AMCase in complex with Compound 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 93 |
Detector technology | CCD |
Collection date | 2006-01-01 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 63.684, 89.248, 125.804 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.800 |
R-factor | 0.19982 |
Rwork | 0.199 |
R-free | 0.22373 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3fy1 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.000 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 1.800 |
Number of reflections | 62892 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |