Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3RK2

Truncated SNARE complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X29A
Synchrotron siteNSLS
BeamlineX29A
Temperature [K]200
Detector technologyCCD
Collection date2010-02-16
DetectorADSC QUANTUM 315
Wavelength(s)0.9797
Spacegroup nameP 1
Unit cell lengths27.627, 39.769, 102.275
Unit cell angles83.38, 89.94, 89.87
Refinement procedure
Resolution39.500 - 2.200
R-factor0.23
Rwork0.227
R-free0.26800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1kil
RMSD bond length0.017
RMSD bond angle1.582
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.280
High resolution limit [Å]2.2002.200
Number of reflections20205
Completeness [%]91.976.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION6.52940.05 M calcium acetate, 27% 2-methyl-2,4-pentanediol (MPD), 0.1 M sodium cacodylate pH 6.5-7.0, VAPOR DIFFUSION, temperature 294K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon