3NVQ

Molecular mechanism of guidance cue recognition

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2009-10-10
DetectorMAR scanner 300 mm plate
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths99.645, 126.078, 236.419
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.400 - 2.400
R-factor0.248
Rwork0.248
R-free0.27700
RMSD bond length0.007
RMSD bond angle1.500
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSOLVE
Refinement softwareCNS (1.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.440
High resolution limit [Å]2.4002.400
Rmerge0.0490.468
Number of reflections114947
<I/σ(I)>29.82.1
Completeness [%]98.686.8
Redundancy4.32.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529512% PEG1000, 0.1M Tris pH7.5, 0.2M Li2SO4, VAPOR DIFFUSION, SITTING DROP, temperature 295K