3NVQ
Molecular mechanism of guidance cue recognition
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-D |
Synchrotron site | APS |
Beamline | 21-ID-D |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2009-10-10 |
Detector | MAR scanner 300 mm plate |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 99.645, 126.078, 236.419 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 25.400 - 2.400 |
R-factor | 0.248 |
Rwork | 0.248 |
R-free | 0.27700 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.500 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SOLVE |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.440 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.049 | 0.468 |
Number of reflections | 114947 | |
<I/σ(I)> | 29.8 | 2.1 |
Completeness [%] | 98.6 | 86.8 |
Redundancy | 4.3 | 2.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 295 | 12% PEG1000, 0.1M Tris pH7.5, 0.2M Li2SO4, VAPOR DIFFUSION, SITTING DROP, temperature 295K |