3MUJ

Early B-cell factor 3 (EBF3) IPT/TIG and dimerization helices

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2009-11-26
DetectorRAYONIX MX-225
Spacegroup nameP 65
Unit cell lengths134.680, 134.680, 41.150
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.100 - 1.920
R-factor0.171
Rwork0.170
R-free0.19300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3mqi
RMSD bond length0.015
RMSD bond angle1.476
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.5_2))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.1001.960
High resolution limit [Å]1.9201.920
Rmerge0.0570.473
Number of reflections32303
<I/σ(I)>30.824.64
Completeness [%]94.017.3
Redundancy9.113.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
16.92770.1M BTP, 0.2M Naformate, 21% PEG3350, pH 6.9, VAPOR DIFFUSION, SITTING DROP, temperature 277K

219869

PDB entries from 2024-05-15